November 17, 2026 · Buying Guide
Laser Tube Cutting Machine Installation: Site and Utility Checklist (2026)
A 3 kW tube laser wants three-phase 380 V five-wire with under 2.5 percent phase unbalance, 200 mm of concrete at 30 N/mm2 or better, nitrogen at 99.99 percent and about 1.5 m3/min, and clear floor for the full bar length. Power and gas delay more installations than the machine build ever does.
I have commissioned tube lasers in Vietnam, Poland, Turkey and Mexico. The machine usually arrives on schedule. The site often does not.
This is the checklist we send 30 days before shipment. Most of it is not about the laser at all.
Space: Measure the Bar, Not the Machine
Space is the first line on any laser tube cutting machine installation checklist, and it is usually the line people estimate. The machine is one number. The loader, the part catcher and the forklift route are the other three.
A 6 m bar machine needs about 12 m of clear length once the loader and part catcher are in. A 9 m machine needs 15 to 16 m. A 12 m machine needs 20 to 22 m, and that is before the forklift turning circle.
| Machine | Bar length | Clear length needed | Width | Weight |
|---|---|---|---|---|
| Standard | 6,000 mm | about 12 m | 3.5 - 4.5 m | 4 - 6 t |
| Long bed | 9,000 mm | 15 - 16 m | 4 - 5 m | 6 - 9 t |
| Long bed | 12,000 mm | 20 - 22 m | 4.5 - 6 m | 9 - 14 t |
Width depends on whether you take a bundle loader and a bevel head. The weight figure is machine plus chiller, not including a transformer on the same pad.
Floor and Foundation
Baseline from our installation manual: floor flatness within plus or minus 10 mm, concrete at least 200 mm thick under the bed and legs, compressive strength 30 N/mm2 or better, load capacity above 30 kN/m2.
If the floor vibrates from a press or a big compressor, cut a shock trench or move the machine. A tube laser cutting thin wall will show chatter marks from a floor it does not like.
We anchor on embedded steel plates at floor level, 20 mm thick and 200 x 200 mm, with M12 x 100 expansion bolts. Check that against the foundation drawing and your local code before anyone pours concrete.
Power: The Number One Delay
Three-phase five-wire, 380 V 50 Hz is the standard Chinese build. 400 V and 440 V builds exist for other markets. Phase unbalance must stay under 2.5 percent and line voltage fluctuation under 5 percent. Single-phase 220 V needs plus or minus 5 percent.
Put the machine and the laser on a stabilised supply or an AVR. Do not run the air compressor or the extraction fan through the same regulator. They fight each other and the laser loses.
Ground resistance target is under 4 ohm. Have an electrician test it and give you the reading in writing. I have seen a machine trip on earth fault for a week because the building ground measured 12 ohm.
Load planning: a 3 kW tube laser draws roughly 9 to 10 kW average in production once chiller and extraction are counted. A 6 kW machine plans around 14 to 18 kW. Size the breaker and cable from the rated input on the nameplate, not from the laser wattage.
Assist Gas
| Gas | Purity | Pressure | Flow | Note |
|---|---|---|---|---|
| Oxygen | above 99.6% | 1.0 MPa | 1.0 m3/min | Liquid oxygen needs a vaporiser |
| Nitrogen | 99.99% or better | 2.0 MPa | 1.5 m3/min up to 3 kW; 2.2 m3/min above 3 kW | Dewars or PSA, not cylinders, at volume |
| Compressed air | dry and oil free | up to 3.0 MPa | depends on nozzle | Thin carbon steel only |
Do not run cylinders to empty. Keep at least one atmosphere above working pressure or the machine alarms mid-job and you lose a part.
Nitrogen is the hidden cost of stainless tube. A 3 kW machine on 2 mm 304 uses roughly 15 to 25 m3 per shift at moderate duty. Price that against the local dewar rate before you promise a part price to your customer.
Chiller, Ambient and Dust
The water chiller needs 5 to 35 degrees C ambient, clean air and at least 500 mm of service gap at the rear. Grinding dust from the next bay will clog the condenser in a month.
Use distilled water with the supplied inhibitor. Tap water scales the chiller and scaling shows up as a power drop long before it shows up as a fault code.
Extraction and Safety
Cutting oiled tube makes fume. Plan 2,000 to 3,000 m3/h of extraction at the cutting zone, with a duct route that does not fight the chiller airflow.
The machine is Class 1 enclosed to IEC 60825-1 while the doors are closed and the interlocks work. Service with the doors open needs 1064 nm rated eyewear and a key-controlled laser safety officer, exactly as the manual says. No exceptions for a quick nozzle change.
Installation Schedule
| Day | Work |
|---|---|
| 1 - 2 | Unpack, position, level with a precision level, anchor |
| 3 | Power connection, ground test, chiller fill, air and gas lines |
| 4 | Chuck and support alignment, head check, safety interlock test |
| 5 | Test cuts on three thicknesses, first article measurement |
| 6 | Parameter tuning for your material mix, CAM post check |
| 7 | Operator and programmer training, handover documents |
Add two days if a transformer or gas manifold has to be built on site. Add a week if the floor is not ready when the machine lands.
Acceptance Test: What to Sign Off
Ask for a first-article report, not a demo. Three thicknesses, your drawings if possible, with cut length, squareness, hole position and dross level recorded and signed.
Then check the safety loop yourself. Open a door during a program and confirm the laser stops. It takes two minutes and it is the item people skip.
Our tube laser range page lists the standard test cut we run before shipment. The contact form is the fastest way to send your material list so we can match the test cut to your parts.
The Five Things That Delay Commissioning
- Wrong voltage or phase. A 220 V single-phase site and a 380 V machine is a two week standstill.
- No earth reading. Somebody assumed the building ground was fine.
- Nitrogen contract not signed. The machine runs, the stainless does not.
- Floor not level or not cured. Anchors pull out and alignment is lost in a month.
- No forklift booked for the day. The machine sits on the truck.
Send the site checklist back to us filled in two weeks before shipment and we will flag what is missing. This has saved more installation time than any machine option we sell.
Frequently Asked Questions
What power supply does a laser tube cutting machine need?
Three-phase five-wire 380 V 50 Hz for the standard Chinese build, with 400 V or 440 V builds for other markets. Phase unbalance under 2.5 percent, voltage fluctuation under 5 percent, ground resistance under 4 ohm. Read the nameplate before you buy cable.
How much floor space does a 6 m tube laser need?
About 12 m of clear length including loader and part catcher, and 3.5 to 4.5 m wide. A 12 m bar machine needs 20 to 22 m of clear length.
What nitrogen purity and flow does a tube laser need?
99.99 percent purity minimum at 2.0 MPa, about 1.5 m3/min up to 3 kW and 2.2 m3/min above 3 kW. Liquid dewars with a vaporiser are cheaper than cylinders at any real volume.
How long does installation take?
Five to seven working days including operator training, if power, floor and gas are ready. Most overruns are site issues, not machine issues.
Can I run a tube laser on a generator?
Not recommended for the laser source. If you have no choice, size the generator at 1.5 to 2 times the rated input and put a stabiliser in front of the machine. Unstable frequency has damaged laser sources before.
Related Articles
- Laser Tube Cutting Machine Price and Cost Guide 2026
- Laser Tube Cutting Machine Procurement Guide: Import From China 2026
- Laser Tube Cutting Machine Sample Test and Trial Guide 2026
- Automatic Tube Laser Loading and Zero Tail Scrap: Setup Guide 2026
- Laser Tube Cutting Machine Maintenance Guide 2026
- Fiber Laser Cutting Machine Price 2026: 3 kW, 6 kW and 12 kW FOB China
Sources: GWEIKE fiber laser installation requirements checklist, 2026 (floor, power quality, grounding, gas purity and flow); Flatpack Laser fiber laser installation requirements, 2026; TRUMPF TruLaser Tube technical data 2026 (average power input in production); FANY LASER installation manuals and commissioning records for 1.5-6 kW tube lasers, 2026; IEC 60825-1 laser safety classification. Values are typical and must be confirmed against the machine nameplate and local code.